Alarm Interface Utility Software V3.1.3
Jumper Setting
DVIF10 (Single or w/Slave) Scope Transmitters On Slave 2 & 3
Cable Null Modem
Cat 5 Standard LAN
Jumper - Shorted JP1, JP2, TP4, J5, JP14
TP4 J5, JP14
Jumper – Removed JP13, JP15
JP1, JP2, JP13, JP15
Jumper - Pins 1 & 2 , JP16, JP17
Same
DVIF10(Single or w/Slave) SPS5V7 and TX125-EN On Slave 2 & 3
Cable Standard Serial Straight Through
Cat 5 Standard LAN
Jumper - Shorted JP1, JP2,
Jumper – Removed TP4, J5, JP13, JP14, JP15
JP1, JP2, TP4, JP19, JP13,14,
JP15
Jumper - Pins 1 & 2 , JP16, JP17
Same
TP4
10
J5
JP16
JP17
Contact Input Voltage or Dry (no voltage)
5. Dry Normally Open (N/O)
a. Alarm Message CLOSED state.
b. Reset Message OPEN state.
c. Repeats will occur on Closed State.
Top to Bottom
JP13, JP14, JP15
Contact Input Fuse 25vdc/450mA JP1
Input Terminal Block 1-10 JP2
Input Jumpers
Fuses
PIC Processor
No Jumper - Voltage
Jumper – No Voltage